> For the complete documentation index, see [llms.txt](https://resources.viewrail.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://resources.viewrail.com/install/forms/angle-wall-measurement-form.md).

# Angle Wall Measurement Form

Customer Name: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_          Date: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\
Order Number: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_        Run #: \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/aZ5mMD8FU3IDcmmCud0f) &#x20;
{% endcolumn %}

{% column width="25%" valign="middle" %}
Knee Wall Angle:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Degree)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
Use an angle finding app or tool to get accurate angle measurements.
{% endhint %}

{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/KNWHpt1AOurCSk5MsFZA) &#x20;
{% endcolumn %}

{% column width="25%" valign="middle" %}
Knee Wall Height:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Inches)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
Measured from the nosing to the top of the finished surface of the knee wall
{% endhint %}

{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/ZoE3EHa5zLd2d2V6WN9A) &#x20;
{% endcolumn %}

{% column width="25%" valign="middle" %}
Front Knee Wall Height:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Inches)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
This is measured from the floor, vertically to the start of the angle run.
{% endhint %}

{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/P33EfKEhZI1LTzJnRItD) &#x20;
{% endcolumn %}

{% column width="25%" valign="middle" %}
Knee Wall Width:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Inches)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
Measurement of the finished knee wall surface. Measurements below 4" will require the use of Narrow Angle Feet.
{% endhint %}
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/2ixBnxcgmdYQUkFxILDT)
{% endcolumn %}

{% column width="25%" valign="middle" %}
Knee Wall Length:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Inches)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
This is the overall length of the angle run
{% endhint %}
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/xMAT1Y94Fr8xr1LCY3yi)
{% endcolumn %}

{% column width="25%" valign="middle" %}
Transition Length:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Inches)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
This is the distance from the last riser to the angle wall, along the level surface
{% endhint %}
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/zbkVMXRLXvtKyUUpQyXO)
{% endcolumn %}

{% column width="25%" valign="middle" %}
Handrail Height:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %} <i class="fa-circle">:circle:</i> Residential (36")

<i class="fa-circle">:circle:</i> Commercial (42")
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
This is the measurement from the tread nosing to the top of the handrail. 36" is standard for residential, 42" is the commercial standard.
{% endhint %}
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/QFravAheGxGeVT0OUsJQ)
{% endcolumn %}

{% column width="25%" valign="middle" %}
Top Post Configuration:
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %} <i class="fa-circle">:circle:</i> Floor

<i class="fa-circle">:circle:</i> Pony Wall
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
Does the top post, that transitions from the angled run to the level run, sit on the floor or does it sit on a pony/knee wall?
{% endhint %}
{% endcolumn %}
{% endcolumns %}

{% columns %}
{% column width="16.666666666666664%" valign="middle" %}
![](/files/kx5cCxtvmVbE1rKOTObP)
{% endcolumn %}

{% column width="25%" valign="middle" %}
Pony Wall Height:\
\&#xNAN;*(if applicable)*
{% endcolumn %}

{% column width="24.999999999999993%" valign="middle" %}
\_\_\_\_\_\_\_\_\_\_\_<sup>(Inches)</sup>
{% endcolumn %}

{% column width="33.33333333333333%" valign="middle" %}
{% hint style="info" %}
If the level railing at the top of the stairs sits on pony/knee wall, what is the height of the wall?
{% endhint %}
{% endcolumn %}
{% endcolumns %}

<figure><img src="/files/8DV7Np54P3wfQ1ldc4LC" alt=""><figcaption></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://resources.viewrail.com/install/forms/angle-wall-measurement-form.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
